Cooper&Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V

Cooper&Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V

No installation
$3,312.75
Skip to product information
Cooper&Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V

Cooper&Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V

$3,312.75
Line Set Length
Cooper&Hunter Light Commercial Hyper ? Multi-Position AHU ? R410A ? 208¨C230V

Cooper&Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V

System: CH-48AHU + CH-NHPR48LCU-230VO

Overview

Cooper&Hunter multi-position air handler units are a versatile replacement for traditional ducted systems, designed to connect to pre-existing ductwork while delivering quieter operation and improved efficiency with a variable-speed fan motor. This bundle pairs the CH-48AHU indoor air handler with the CH-NHPR48LCU-230VO Light Commercial Hyper outdoor unit for a single-zone, ducted heat pump split system using R410A.

The AHU supports vertical, horizontal, or downflow installation and can be connected to a standard 24V wall thermostat. The Hyper outdoor option provides dependable heating down to -22¡ãF ambient.

Highlights

Single Zone bundle Multi-position install (IDU) 24V thermostat compatible High static pressure (ESP 0¨C0.8) Heat to -22¡ãF (ODU) R410A refrigerant Indoor SEER2: 16.2 Outdoor SEER2: 14.6 Lines: 3/8" ? 5/8" Max line: 213.25 ft AHRI Ref: 210799615
  • Ductwork-friendly: built to integrate with existing ducts for a cleaner retrofit path.
  • Quiet operation: variable-speed fan motor and staged airflow.
  • Flexible install: vertical, horizontal, or downflow configurations.
  • Control flexibility: compatible with standard 24V thermostat; also supports RG10D remote + wired controller (120X/120N).
  • Cold-climate heating: outdoor operation down to -22¡ãF ambient in heating mode.
IndoorCH-48AHU
OutdoorCH-NHPR48LCU-230VO
ESP range0¨C0.8
Max run213.25 ft

What¡¯s Included

  • Indoor air handler unit: CH-48AHU
  • Outdoor Light Commercial Hyper condenser: CH-NHPR48LCU-230VO
  • Remote/control support: RG10D standard remote & 120X or 120N wire controller compatibility
  • Manufacturer documentation (see Documents & Downloads)
  • Installation kits are not included unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).

Indoor Specs

Spec Details
Model CH-48AHU
System type Single-zone unit
Refrigerant type R410A
BTU rated 48,000
Power source 208¨C230V, 1Ph, 60Hz
Voltage range 187¨C253 V
Dehumidification 10.82 pnt/day
EER2 8.6
SEER2 16.2
Refrigerant piping (liq/gas) 3/8" / 5/8"
Filter dimensions (W¡ÁD) 19.40 ¡Á 20.35 in
Minimum circuit ampacity 7.5
Max fuse 15
Indoor noise level (H/M/L) 53.5 / 47 / 43.5 dB(A)
Indoor air flow 1,470.59 / 1,282.35 / 1,094.12 / 905.88 CFM
ESP range 0 ¨C 0.8
Drain pipe diameter 1"
Operating range (Cooling) 60¨C90¡ãF
Operating range (Heating) 32¨C86¡ãF
Controller RG10D standard remote & 120X or 120N wire controller
Unit dimensions (W¡ÁH¡ÁD) 21.02 ¡Á 21.02 ¡Á 49.02 in
Net / Gross weight 132.50 / 155.87 lb
Packing dimensions (W¡ÁD¡ÁH) 26.57 ¡Á 24.41 ¡Á 52.56 in

Outdoor Specs

Spec Details
Model CH-NHPR48LCU-230VO
System type Single-zone unit
Refrigerant type R410A
BTU rated 48,000
Power source 208¨C230V, 1Ph, 60Hz
Voltage range 187¨C253 V
Dehumidification 10.82 pnt/day
Refrigerant piping (liq/gas) 3/8" / 5/8"
Max pipe length 213.25 ft
Max height difference (IDU?ODU) 98.42 ft
Cooling capacity (Min/Max) 47,000 (9,500¨C48,500) BTU/h
Heating capacity (Min/Max) 48,000 (10,500¨C55,000) BTU/h
SEER2 14.6
EER2 7.8
HSPF2-5 7.3
HSPF2-4 8.8
COP 2.96
Outdoor noise level 64 dB(A)
Outdoor air flow 4,500 CFM
Minimum circuit ampacity 40
Max fuse 50
Ambient temp (Heating) -22¨C75¡ãF
Ambient temp (Cooling) 5¨C122¡ãF
Unit dimensions (W¡ÁH¡ÁD) 37.48 ¡Á 16.34 ¡Á 52.48 in
Net / Gross weight 227.07 / 255.73 lb
Packing dimensions (W¡ÁD¡ÁH) 43.11 ¡Á 19.49 ¡Á 58.27 in
Refrigerant precharge 25
Additional charge (3/8" liquid) 0.32

Documents & Downloads

  • AHRI Directory Reference ¡ª 210799615

Important

  • Confirm thermostat selection (24V), duct sizing/static pressure, electrical requirements, line sizes, and maximum line length/height limits before installation.
  • Installation kits are not included unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).

FAQs

Is this a single-zone system?
Yes¡ªthis is a single-zone bundle pairing CH-48AHU with CH-NHPR48LCU-230VO.
Can this connect to a standard wall thermostat?
Yes. The air handler is compatible with a standard 24V wall thermostat.
What installation orientations are supported?
The air handler can be installed vertically, horizontally, or in a downflow configuration.
How cold can it heat?
The Hyper outdoor unit operates in heating down to -22¡ãF ambient.
Are installation kits included?
No. Installation kits are only included if selected on the Variant Options (No installation, 16ft, 25ft, 50ft).