{"product_id":"cooper-hunter-48-000-btu-hyper-high-efficiency-multi-position-air-handler-unit-ducted-heat-pump-split-system-r410a-230v","title":"Cooper\u0026Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V","description":"\u003cstyle\u003e  :root{    --hvx-golden:#FAA819;    --hvx-slate:#262626;    --hvx-ivory:#F4F1E6;    --hvx-border:#e2e0d5;    --hvx-card-bg:#ffffff;  }  .hvx-desc{    font-family:\"Articulat CF\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;    color:var(--hvx-slate);    line-height:1.6;    background:var(--hvx-ivory);    padding:18px 18px 20px;    border-radius:16px;  }  .hvx-desc-header{    border-radius:14px;    padding:14px 16px;    background:linear-gradient(120deg,var(--hvx-golden),var(--hvx-slate));    color:#fff;    margin:0 0 16px;    box-shadow:0 10px 24px rgba(0,0,0,.22);    display:flex;    align-items:flex-start;    gap:12px;    flex-wrap:wrap;  }  .hvx-header-text{display:flex;flex-direction:column;gap:6px;min-width:260px}  .hvx-eyebrow{    font-size:11px;    letter-spacing:.14em;    text-transform:uppercase;    opacity:.9;  }  .hvx-title{    margin:0;    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;    font-size:22px;    line-height:1.15;  }  .hvx-subtitle{margin:0;font-size:14px;opacity:.95}  .hvx-desc-card{    border:1px solid var(--hvx-border);    border-radius:14px;    background:var(--hvx-card-bg);    padding:16px 18px 18px;    box-shadow:0 4px 12px rgba(0,0,0,.06);    margin:14px 0;  }  .hvx-section-title{    margin:0 0 10px;    font-family:\"Anton\",\"Impact\",system-ui,-apple-system,BlinkMacSystemFont,\"Segoe UI\",sans-serif;    font-size:17px;    letter-spacing:.08em;    text-transform:uppercase;    color:var(--hvx-slate);    display:inline-flex;    align-items:center;    gap:8px;  }  .hvx-section-title::after{    content:\"\";    flex:1;    height:2px;    border-radius:999px;    background:linear-gradient(90deg,var(--hvx-golden),transparent);    opacity:.9;  }  .hvx-cta{display:flex;flex-wrap:wrap;gap:10px;margin:10px 0 0}  .hvx-cta a{    display:inline-flex;    align-items:center;    gap:8px;    padding:10px 14px;    border-radius:12px;    border:1px solid var(--hvx-border);    background:#fff;    text-decoration:none;    color:var(--hvx-slate);    font-size:14px;    font-weight:700;  }  .hvx-cta a.primary{    background:var(--hvx-slate);    color:#fff;    border-color:transparent;  }  .hvx-badges{display:flex;flex-wrap:wrap;gap:8px;margin:10px 0 0}  .hvx-badge{    font-size:12px;    border:1px solid var(--hvx-border);    border-radius:999px;    padding:6px 10px;    background:#fff;    white-space:nowrap;  }  .hvx-kv{    display:grid;    grid-template-columns:repeat(4,minmax(160px,1fr));    gap:10px;    margin-top:10px;  }  .hvx-kv \u003e div{    border:1px solid var(--hvx-border);    background:#fff;    border-radius:12px;    padding:10px 12px;    text-align:center;  }  .hvx-kv strong{display:block}  .hvx-table{    width:100%;    border-collapse:collapse;    min-width:520px;    background:#fff;    border:1px solid var(--hvx-border);    border-radius:12px;    overflow:hidden;  }  .hvx-table th,.hvx-table td{    border-bottom:1px solid var(--hvx-border);    padding:10px 12px;    vertical-align:top;    font-size:14px;  }  .hvx-table th{ text-align:left; font-weight:800; background:#fff; }  .hvx-table tr:nth-child(even) td{ background:#fbfaf6; }  .hvx-table tr:last-child td{ border-bottom:none; }  .hvx-table-wrap{ overflow:auto; border-radius:12px; }  .hvx-link{color:var(--hvx-slate); text-decoration:underline; text-underline-offset:2px}  .hvx-link:hover{opacity:.85}  details.hvx-faq{    border:1px solid var(--hvx-border);    background:#fff;    border-radius:12px;    padding:10px 12px;    margin:8px 0;  }  details.hvx-faq summary{cursor:pointer;font-weight:800}  @media(max-width:980px){    .hvx-kv{grid-template-columns:repeat(2,minmax(160px,1fr))}  }  @media(max-width:768px){    .hvx-desc{padding:14px 12px 16px;border-radius:12px}    .hvx-desc-header{padding:12px;border-radius:12px}    .hvx-title{font-size:19px}    .hvx-desc-card{padding:14px;margin:10px 0}  }\u003c\/style\u003e\u003cdiv class=\"hvx-desc\"\u003e\n\u003cdiv class=\"hvx-desc-header\"\u003e\u003cdiv class=\"hvx-header-text\"\u003e\n\u003cdiv class=\"hvx-eyebrow\"\u003eCooper\u0026amp;Hunter Light Commercial Hyper ? Multi-Position AHU ? R410A ? 208¨C230V\u003c\/div\u003e\n\u003ch1 class=\"hvx-title\"\u003eCooper\u0026amp;Hunter 48,000 BTU Hyper High Efficiency Multi Position Air Handler Unit Ducted Heat Pump Split System R410A 230V\u003c\/h1\u003e\n\u003cp class=\"hvx-subtitle\"\u003e\u003cstrong\u003eSystem:\u003c\/strong\u003e CH-48AHU + CH-NHPR48LCU-230VO\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv aria-label=\"Contact options\" class=\"hvx-cta\"\u003e \u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eCooper\u0026amp;Hunter \u003cstrong\u003emulti-position air handler units\u003c\/strong\u003e are a versatile replacement for traditional ducted systems, designed to connect to \u003cstrong\u003epre-existing ductwork\u003c\/strong\u003e while delivering quieter operation and improved efficiency with a variable-speed fan motor. This bundle pairs the \u003cstrong\u003eCH-48AHU\u003c\/strong\u003e indoor air handler with the \u003cstrong\u003eCH-NHPR48LCU-230VO\u003c\/strong\u003e Light Commercial Hyper outdoor unit for a \u003cstrong\u003esingle-zone\u003c\/strong\u003e, ducted heat pump split system using \u003cstrong\u003eR410A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin: 10px 0 0;\"\u003eThe AHU supports \u003cstrong\u003evertical, horizontal, or downflow\u003c\/strong\u003e installation and can be connected to a standard \u003cstrong\u003e24V wall thermostat\u003c\/strong\u003e. The Hyper outdoor option provides dependable heating down to \u003cstrong\u003e-22¡ãF\u003c\/strong\u003e ambient.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eHighlights\u003c\/h2\u003e\n\u003cdiv role=\"list\" class=\"hvx-badges\"\u003e\n\u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eSingle Zone bundle\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMulti-position install (IDU)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003e24V thermostat compatible\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHigh static pressure (ESP 0¨C0.8)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eHeat to -22¡ãF (ODU)\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eR410A refrigerant\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eIndoor SEER2: 16.2\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eOutdoor SEER2: 14.6\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eLines: 3\/8\" ? 5\/8\"\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eMax line: 213.25 ft\u003c\/span\u003e \u003cspan role=\"listitem\" class=\"hvx-badge\"\u003eAHRI Ref: 210799615\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul style=\"margin: 12px 0 0; padding-left: 18px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuctwork-friendly:\u003c\/strong\u003e built to integrate with existing ducts for a cleaner retrofit path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet operation:\u003c\/strong\u003e variable-speed fan motor and staged airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible install:\u003c\/strong\u003e vertical, horizontal, or downflow configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl flexibility:\u003c\/strong\u003e compatible with standard 24V thermostat; also supports RG10D remote + wired controller (120X\/120N).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-climate heating:\u003c\/strong\u003e outdoor operation down to -22¡ãF ambient in heating mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv aria-label=\"At-a-glance\" role=\"list\" class=\"hvx-kv\"\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eIndoor\u003c\/strong\u003eCH-48AHU\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eOutdoor\u003c\/strong\u003eCH-NHPR48LCU-230VO\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eESP range\u003c\/strong\u003e0¨C0.8\u003c\/div\u003e\n\u003cdiv role=\"listitem\"\u003e\n\u003cstrong\u003eMax run\u003c\/strong\u003e213.25 ft\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eWhat¡¯s Included\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003eIndoor air handler unit: CH-48AHU\u003c\/li\u003e\n\u003cli\u003eOutdoor Light Commercial Hyper condenser: CH-NHPR48LCU-230VO\u003c\/li\u003e\n\u003cli\u003eRemote\/control support: RG10D standard remote \u0026amp; 120X or 120N wire controller compatibility\u003c\/li\u003e\n\u003cli\u003eManufacturer documentation (see Documents \u0026amp; Downloads)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (\u003cstrong\u003eNo installation\u003c\/strong\u003e, \u003cstrong\u003e16ft\u003c\/strong\u003e, \u003cstrong\u003e25ft\u003c\/strong\u003e, \u003cstrong\u003e50ft\u003c\/strong\u003e).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eIndoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\u003ctable aria-label=\"Indoor air handler specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-48AHU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208¨C230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187¨C253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.82 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilter dimensions (W¡ÁD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.40 ¡Á 20.35 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor noise level (H\/M\/L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.5 \/ 47 \/ 43.5 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,470.59 \/ 1,282.35 \/ 1,094.12 \/ 905.88 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eESP range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ¨C 0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain pipe diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60¨C90¡ãF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating range (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32¨C86¡ãF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRG10D standard remote \u0026amp; 120X or 120N wire controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W¡ÁH¡ÁD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.02 ¡Á 21.02 ¡Á 49.02 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132.50 \/ 155.87 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W¡ÁD¡ÁH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.57 ¡Á 24.41 ¡Á 52.56 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eOutdoor Specs\u003c\/h2\u003e\n\u003cdiv class=\"hvx-table-wrap\"\u003e\u003ctable aria-label=\"Outdoor unit specifications\" class=\"hvx-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH-NHPR48LCU-230VO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-zone unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBTU rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208¨C230V, 1Ph, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e187¨C253 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDehumidification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.82 pnt\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant piping (liq\/gas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" \/ 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pipe length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e213.25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax height difference (IDU?ODU)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.42 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47,000 (9,500¨C48,500) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity (Min\/Max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 (10,500¨C55,000) BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCOP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor noise level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutdoor air flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,500 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Heating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-22¨C75¡ãF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temp (Cooling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5¨C122¡ãF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions (W¡ÁH¡ÁD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.48 ¡Á 16.34 ¡Á 52.48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet \/ Gross weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e227.07 \/ 255.73 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking dimensions (W¡ÁD¡ÁH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.11 ¡Á 19.49 ¡Á 58.27 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant precharge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional charge (3\/8\" liquid)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eDocuments \u0026amp; Downloads\u003c\/h2\u003e\n\u003cul style=\"padding-left: 18px; margin: 8px 0;\"\u003e\n\u003cli\u003e\n\u003cli\u003e\n\u003cli\u003e\n\u003cli\u003e\n\u003cli\u003e\n\u003cli\u003e\n\u003cli\u003eAHRI Directory Reference ¡ª 210799615\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eVideos\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 8px;\"\u003e\u003cstrong\u003eFeatured video\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin: 0 0 12px;\"\u003e\u003ciframe title=\"Multi Position Air Handler\" src=\"https:\/\/www.youtube.com\/embed\/pvnUzLYgcBk\" height=\"315\" width=\"560\"\u003e      \u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"margin: 0 0 6px;\"\u003e\u003cstrong\u003eProducts overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\n\u003cli\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 12px 0 6px;\"\u003e\u003cstrong\u003eAHU\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/pvnUzLYgcBk\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMulti Position Air Handler\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp style=\"margin: 12px 0 6px;\"\u003e\u003cstrong\u003eOutdoor unit video groups\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin: 0;\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/Cxuiytm_CMo\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eHow to Install Multi Zone Mini Split System (Cooper\u0026amp;Hunter) 2020\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/JQkth-AM5CE\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of Mini Split Ductless Unit, Step by Step!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/7mzwevkxw20\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eTop Tips from Cooper\u0026amp;Hunter Mini Split User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/Z7jhBvW4uw8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eCooper\u0026amp;Hunter New Remote Control (2022)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/2u0pa2jThCM\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eHVAC Installation Kit: 99.9% Copper Line Sets (Cooper\u0026amp;Hunter)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/qCWu8HCNl3Q\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Indoor Unit Types Explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=n00qcO3iIR0\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eCan You Use a Mini Split in EXTREME COLD? Heat Pump vs. Propane Cost Comparison with Thermal Camera\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=5QgZqyFp334\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eWhere To Mount a Mini Split Indoor Wall Hung Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=hxYrOv5bV9Y\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eHow To Wall Mount a Mini Split Outdoor Condenser Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=3DHyShrGUXw\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eAre Mini Split Air Conditioners Worth It? - Top 5 Pros \u0026amp; Cons\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=USU0xujHHL8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eDoes a Wall Mounted MINISPLIT Need a CONDENSATE TRAP? Ductless vs Ducted Air Handlers!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=ATk1fx_N_qc\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMINI SPLIT Parts Explained! Understand What They Do!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=-GHFRcvQwNA\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eMini Split Failure from Electrical Surges, High and Low Voltage! HOW TO SOLVE IT!\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=ZNRlS2xOcVc\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eFull Installation of an Inverter Minisplit Heat Pump with Indoor Ceiling Cassette\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=BxMwbC_2ow8\" rel=\"noopener\" class=\"hvx-link\" target=\"_blank\"\u003eChecking the Refrigerant Charge on a Running R-410A Inverter MINI SPLIT Unit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eImportant\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 18px; font-size: 14px;\"\u003e\n\u003cli\u003eConfirm thermostat selection (24V), duct sizing\/static pressure, electrical requirements, line sizes, and maximum line length\/height limits before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation kits are not included\u003c\/strong\u003e unless selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hvx-desc-card\"\u003e\n\u003ch2 class=\"hvx-section-title\"\u003eFAQs\u003c\/h2\u003e\n\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eIs this a single-zone system?\u003c\/summary\u003e\u003cdiv style=\"margin-top: 8px;\"\u003eYes¡ªthis is a \u003cstrong\u003esingle-zone bundle\u003c\/strong\u003e pairing CH-48AHU with CH-NHPR48LCU-230VO.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eCan this connect to a standard wall thermostat?\u003c\/summary\u003e\u003cdiv style=\"margin-top: 8px;\"\u003eYes. The air handler is compatible with a \u003cstrong\u003estandard 24V wall thermostat\u003c\/strong\u003e.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eWhat installation orientations are supported?\u003c\/summary\u003e\u003cdiv style=\"margin-top: 8px;\"\u003eThe air handler can be installed \u003cstrong\u003evertically\u003c\/strong\u003e, \u003cstrong\u003ehorizontally\u003c\/strong\u003e, or in a \u003cstrong\u003edownflow\u003c\/strong\u003e configuration.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eHow cold can it heat?\u003c\/summary\u003e\u003cdiv style=\"margin-top: 8px;\"\u003eThe Hyper outdoor unit operates in heating down to \u003cstrong\u003e-22¡ãF\u003c\/strong\u003e ambient.\u003c\/div\u003e\u003c\/details\u003e\u003cdetails open=\"\" class=\"hvx-faq\"\u003e\u003csummary\u003eAre installation kits included?\u003c\/summary\u003e\u003cdiv style=\"margin-top: 8px;\"\u003eNo. Installation kits are only included if selected on the Variant Options (No installation, 16ft, 25ft, 50ft).\u003c\/div\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"mysite","offers":[{"title":"No installation","offer_id":50219642716403,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":3312.75,"currency_code":"USD","in_stock":true},{"title":"16FT","offer_id":50219642749171,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4424.76,"currency_code":"USD","in_stock":true},{"title":"25FT","offer_id":50219642781939,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4562.46,"currency_code":"USD","in_stock":true},{"title":"50FT","offer_id":50219642814707,"sku":"CH-48AHU + CH-NHPR48LCU-230VO","price":4888.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0846\/0229\/0419\/files\/Untitled_design_19_2.png?v=1786010011","url":"https:\/\/hvacsupplies.shop\/products\/cooper-hunter-48-000-btu-hyper-high-efficiency-multi-position-air-handler-unit-ducted-heat-pump-split-system-r410a-230v","provider":"HVAC Supplies","version":"1.0","type":"link"}